Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Braz. dent. sci ; 25(3): 1-8, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1373117

ABSTRACT

Objective: To evaluate the ability of different separating mediums to prevent adhesion between provisional restorations and hybridized dentin surfaces when used with the Immediate Dentin Sealing technique (IDS). Material and Methods: 120 extracted human teeth ­ 40 premolars and 80 molars ­ were selected to integrate acrylics samples separated into 4 different groups (n=10) according to the separating medium used for IDS protection. Forty samples were made of three teeth mounted in a self-cure acrylic resin block (Jet, Classic, São Paulo, Brazil) arranged side by side, simulating the positioning and proximal contacts present in the dental arch between the second premolar, first molar and second molar. A standard dental preparation for ultra-thin occlusal veneer was performed and complete occlusal dentin exposure was achieved by selective removal of the occlusal enamel with a high-speed conical round burr (Code: 1801.4138 FG, KG Sorensen, Medical Burs Ind. e Com. de Pontas e Brocas Cirúrgicas Ltda, São Paulo, Brazil). Dentin hybridization were performed on the control group and 3 different groups of separating mediums (n=10): PC­commercial provisional separating agent (Pro-V Coat, Bisco, Schaumburg, USA); GG­glycerin gel (K-Y Gel; Johnson & Johnson Industry and Commerce LTDA, São Paulo, Brazil); PJ­petroleum jelly (Rioquímica, São Paulo, Brazil). Provisionalization were manufactured on the prepared teeth. After 2 weeks, the tensile test was performed, and the analysis of the failure pattern was performed by 3D laser confocal microscopy and Scanning Electron Microscopy (SEM). The data were analyzed with the 1-way ANOVA and the Tukey test (α = 0.05). Results: Significantly lower tensile strength values were found for the commercial provisional separating agent (30.39 ± 10.01 N) compared to others (p < 0.05). Conclusion: The commercial provisional separating agent showed greater effectiveness on protecting hybridized dentin against the provisional restorations (AU)


Objetivo: Avaliar a capacidade de diferentes agentes isolantes em prevenir a adesão entre as restaurações provisórias e a superfícies de dentina hibridizadas quando usados com a técnica do Selamento Dentinário Imediato (IDS). Material e Métodos: 120 dentes humanos extraídos - 40 pré-molares e 80 molares - foram selecionados para integrar as amostras de acrílico divididas em 4 grupos diferentes (n = 10) de acordo com o meio de separação usado para proteção IDS. Foram confeccionadas 40 amostras de três dentes montados em um bloco de resina acrílica autopolimerizável (Jet, Classic, São Paulo, Brasil) dispostos lado a lado, simulando o posicionamento e os contatos proximais presentes na arcada dentária entre o segundo pré-molar, primeiro molar e segundo molar. Um preparo dentário padrão para laminado oclusal ultrafino foi realizado e a exposição completa da dentina oclusal foi obtida pela remoção seletiva do esmalte oclusal com uma broca cônica arredondada de alta rotação (Código: 1801.4138 FG, KG Sorensen, Medical Burs Ind. E Com. de Pontas e Brocas Cirúrgicas Ltda, São Paulo, Brasil). A hibridização da dentina foi realizada no grupo controle e em 3 grupos diferentes de agentes isolantes (n = 10): PC - agente de separação provisório comercial (Pro-V Coat, Bisco, Schaumburg, EUA); GG ­ gel de glicerina (K-Y Gel; Johnson & Johnson Industry and Commerce LTDA, São Paulo, Brasil); PJ ­ vaselina (Rioquímica, São Paulo, Brasil). As restaurações provisórias foram fabricadas nos dentes preparados. Após 2 semanas, foi realizado o teste de tração, e a análise do padrão de falha foi realizada por microscopia confocal a laser 3D e Microscopia Eletrônica de Varredura (MEV). Os dados foram analisados com a ANOVA de 1 fator e o teste de Tukey (α = 0,05). Resultados: Valores de resistência à tração significativamente menores foram encontrados para o agente separador provisório comercial (30,39 ± 10,01 N) em comparação com os demais (p < 0,05). Conclusão: O agente separador provisório comercial mostrou maior eficácia para a proteção da dentina hibridizada contra as restaurações provisórias (AU)


Subject(s)
Humans , Dentin-Bonding Agents , Dental Restoration, Temporary , Dentin
2.
Braz. dent. j ; 22(5): 359-364, 2011. tab
Article in English | LILACS | ID: lil-601834

ABSTRACT

This study investigated the effects of the cement type and the water storage time on the push-out bond strength of a glass fiber post. Glass fiber posts (Fibrekor, Jeneric Pentron) were luted to post spaces using a self-cured resin cement (C&B Cement [CB]), a glass ionomer cement (Ketac Cem [KC]) or a resin-modified glass ionomer cement (GC FujiCEM [FC]) according to the manufacturers’ instructions. For each luting agent, the specimens were exposed to one of the following water storage times (n=5): 1 day (T1), 7 days (T7), 90 days (T90) and 180 days (T180). Push-out tests were performed after the storage times. Control specimens were not exposed to water storage, but subjected to the push-out test 10 min after post cementation. Data (in MPa) were analyzed by Kruskal-Wallis and Dunn`s test (α=0.05). Cement type and water storage time had a significant effect (p<0.05) on the push-out bond strength. CB showed significantly higher values of retention (p<0.05) than KC and FC, irrespective of the water storage time. Water storage increased significantly the push-out bond strength in T7 and T90, regardless of the cement type (p<0.05). The results showed that fiber posts luted to post spaces with the self-cured resin cement exhibited the best bonding performance throughout the 180-day water storage period. All cements exhibited a tendency to increase the bond strength after 7 and 90 days of water storage, decreasing thereafter.


Este estudo investigou os efeitos do tipo de cimento e do tempo de armazenamento em água na resistência adesiva ao cisalhamento de pinos de fibra. Pinos de fibra de vidro (Fibrekor, JenericPentron) foram cimentados aos condutos radiculares usando o cimento resinoso autopolimerizável (C&B Cement [CB]), o cimento de ionômero de vidro (Ketac Cem [KC]) ou o cimento de ionômero de vidro modificado por resina (GC FujiCEM [FC]) de acordo com as instruções dos fabricantes. Para cada cimento, os espécimes foram expostos a um dos seguintes tempos de armazenamento em água (n=5): 1 dia (T1), 7 dias (T7), 90 dias (T90) e 180 dias (T180). Os testes de resistência adesiva ao cisalhamento foram realizados após os períodos de armazenamento. Os espécimes controles não foram expostos ao armazenamento em água, mas submetidos ao teste de resistência adesiva ao cisalhamento 10 min após a cimentação do pino. Os dados (MPa) foram analisados usando Kruskal-Wallis e teste de Dunn (α=0,05). O tipo de cimento e o tempo de armazenamento em água afetaram significantemente a resistência adesiva ao cisalhamento (p<0,05). CB apresentou valores de retenção significantemente superiores a KC e FC, independentemente do tempo de armazenamento em água. Esse, por sua vez, aumentou significantemente a resistência adesiva ao cisalhamento em T7 e T90, independentemente do tipo de cimento (p<0,05). Os resultados indicaram que os pinos de fibra cimentados aos condutos radiculares com o cimento resinoso autopolimerizável apresentou a melhor performance adesiva durante todo o período de armazenamento em água de 180 dias. Todos os cimentos apresentaram uma tendência a aumentar a resistência adesiva ao cisalhamento após 7 e 90 dias de armazenamento em água, diminuindo posteriormente.


Subject(s)
Humans , Dental Bonding , Dental Cements/chemistry , Glass/chemistry , Post and Core Technique/instrumentation , Water/chemistry , Absorption , Adsorption , Boron Compounds/chemistry , Composite Resins/chemistry , Dental Cements/classification , Dental Pulp Cavity/anatomy & histology , Dentin/anatomy & histology , Glass Ionomer Cements/chemistry , Materials Testing , Magnesium Oxide/chemistry , Methacrylates/chemistry , Methylmethacrylates/chemistry , Polycarboxylate Cement/chemistry , Resin Cements/chemistry , Root Canal Preparation/methods , Stress, Mechanical , Time Factors , Zinc Oxide/chemistry
3.
RGO (Porto Alegre) ; 57(1): 19-25, jan.-mar. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-873759

ABSTRACT

Objetivo:Avaliar a resistência e o padrão de fratura de dentes tratados endodonticamente com raízes estruturalmente enfraquecidas, reconstruídas com pinos de fibras de polietileno e pinos biológicos. Métodos: Após remoção das coroas, sessenta caninos superiores tratados endodonticamente foram distribuídos em quatro grupos: 1) preparo convencional dos condutos e pinos de fibras de polietileno; 2) preparo convencional dos condutos e pinos biológicos; 3) condutos medianamente alargados e pinos biológicos; 4) condutos amplamente alargados e pinos biológicos. Os pinos foram cimentados com cimento resinoso Enforce (Dentsply Ind. e Com., Petrópolis, Rio de Janeiro, Brasil) e construiu-se a porção coronária com resina composta Ti-Core(Essential Dental Systems, S. Hackensack, NJ, USA). Os espécimes foram testados sob compressão em máquina de ensaios universal. Resultados: Os valores de resistência à fratura obtidos foram: grupo 1 - 45,46kgf; grupo 2 - 53,30kgf; grupo 3 - 58,67kgf; grupo 4 - 47,91kgf, com diferença estatisticamente significante entre os grupos 1 e 3 (p < 0,05). Observou-se o seguinte padrão de fratura: grupo 1 - ampla predominância de fratura da porção coronária do núcleo; grupos 2 e 3 - padrão variado de fraturas; grupo 4 - todas as raízes fraturaram. Conclusão: Ambos os pinos mostraram-se promissores para o uso proposto (adequada resistência à fratura e padrão de fraturas favorável). Os pinos biológicos parecem capazes de promover reforço das raízes, porém 100% das raízes amplamente alargadas fraturaram.


Objective: To investigate the fracture strength and mode of endodontically treated teeth with structurally weakened roots reconstructed withwoven polyethylene fiber posts and biological posts. Methods: After removing the crowns, 60 endodontically treated maxillary canines were distributed into 4 groups: 1) conventional root canal preparation and reconstruction with polyethylene fiber posts; 2) conventional root canal preparation and reconstruction with biological posts; 3) moderately flared root canals and reconstruction with biological posts; 4) widely flared root canals and reconstruction with biological posts. The posts were cemented with resin cement Enforce (Dentsply Ind. e Com., Petrópolis, Rio de Janeiro, Brasil) and the core was constructed with Ti-Core (EssentialDental Systems, S. Hackensack, NJ, USA) resin composite. The specimens were tested under compression in a universal testing machine. Results: The following fracture strength values were obtained: Group 1 - 45.46kgf; Group 2 - 53.30kgf; Group 3 - 58.67kgf; Group 4 - 47.91kgf, with statistically significant differences between Groups 1 and 3 (p<0.05). The following fracture modes were observed: Group 1 - predominance of fracture of the coronal portion of the post; Groups 2 and 3 - various fracture patterns; Group 4 - all roots fractured. Conclusion: Both posts were shown to be promising (adequate fracture strength and favorable pattern of fracture). Biological posts appear to be capable of reinforcing the root to some extent; however, fracture occured in all roots with widely flared root canals.


Subject(s)
Humans , Materials Testing , Post and Core Technique , Case-Control Studies , Tensile Strength
4.
Bauru; s.n; 2009. 198 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-542589

ABSTRACT

A perda de adesão é uma falha comum reportada para os pinos reforçados por fibra e usualmente ocorre ao longo da interface adesiva entre a dentina radicular e o cimento resinoso. A espessura de cimento resinoso ideal para preservar a continuidade da interface adesiva cimento-dentina e aumentar a retenção do pino é desconhecida. O objetivo deste estudo foi avaliar a influência da espessura do cimento na integridade e na resistência adesiva de dois cimentos resinosos empregados para a cimentação de pinos reforçados por fibra. Trinta incisivos laterais superiores humanos com comprimentos radiculares semelhantes foram selecionados, secionados na jução cimento-esmalte e tratados endodonticamente. As raízes foram aleatoriamente divididas em seis grupos (n=5), e os condutos radiculares foram preparados a uma profundidade de 8 mm usando uma das três brocas com diâmetro diferente: Broca Largo n 3 para o grupo controle (L3 1 mm); Broca Largo nℵ 4 (L4 - 1,25 mm) e Broca Largo nℵ 5 (L5 1,5 mm) para os grupos experimentais. Pinos de resina reforçados por fibra de vidro (Fibrekor post, Jeneric Pentron), 1 mm de diâmetro, foram cimentados aos condutos radiculares utilizando o cimento resinoso dual (Duolink, Bisco) ou o cimento resinoso autopolimerizável (C&B Cement, Bisco). A porção de cada espécime contendo os pinos reforçados por fibra foi secionada transversalmente em tres seções (cervical, média e apical) de 2 mm de espessura utilizando um disco diamantado em máquina de corte seriado sob refrigeração com água. As seções foram polidas, limpas ultrassonicamente e duplicadas com polivinil siloxano. Réplicas em resina epoxica das seções foram obtidas para a mensuração da espessura do cimento e da integridade adesiva na interface cimento-dentina por meio de MEV. As seções foram armazenadas em solução fisiológica a 37º C por uma semana e, então, submetidas ao teste push-out em uma máquina de ensaio universal a velocidade de 0,5 mm/min-1, e a força máxima requerida...


Subject(s)
Humans , Dental Bonding/methods , Dental Stress Analysis , Dentin-Bonding Agents , Post and Core Technique , Resin Cements , Analysis of Variance , Cementation/methods , Microscopy, Electron, Scanning
5.
Rev. bras. odontol ; 65(1): 48-51, jan.-jun. 2008. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-541698

ABSTRACT

O presente trabalho avaliou o método de Willis na determinação da dimensão vertical em 39 indivíduos dentados, com idade entre 19 e 45 anos. Uma forte correlação foi observada entre o terço médio da face e a DVR (r=0,73, p = 0,000) e, entre o terço médio e a DVO (r = 0,74, p = 0.000). Não houve diferença significante entre o terço médio e a DVO (p=0.11), contudo foram observadas diferenças entre o terço médio e a DVR (p =0,000), e entre a DVO e a DVR (p = 0.000). A análise estatística indicou que o método de Willis foi adequado na determinação da dimensão vertical de oclusão.


Subject(s)
Humans , Male , Female , Adult , Dental Occlusion , Jaw Relation Record , Vertical Dimension
6.
J. appl. oral sci ; 16(3): 176-180, May-June 2008. ilus, tab
Article in English | LILACS, BBO | ID: lil-483150

ABSTRACT

The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey’s test (á=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth.


Subject(s)
Acrylic Resins , Dental Restoration Wear , Denture, Partial, Removable , Polymethyl Methacrylate , Tooth, Artificial
7.
RGO (Porto Alegre) ; 56(2): 7-13, abr.-jun. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-487241

ABSTRACT

A adequada reconstrução de dentes endodonticamente tratados e com grande perda de tecido dentinário é um dos desafios da Odontologia Restauradora. Nenhum dos pinos intra-radiculares pré-fabricados encontrados no mercado preenche todas as propriedades biológicas e mecânicas ideais. Recentemente, tem sido indicada uma técnica com múltiplas vantagens para reconstrução de dentes despolpados com raízes enfraquecidas, consistindo na utilização de pinos dentários obtidos a partir de dentes naturais. Este artigo apresenta, através de um caso clínico, todos os detalhes necessários para execução da técnica.


Adequate reconstruction of endodontically treated teeth with severe loss of dentine tissue is one of the challenges of Restorative Dentistry. None of the commercially available pre-fabricated intraradicular posts meets all ideal biological and mechanical properties. Recently, a technique for the reconstruction of pulpless teeth with weakened roots has been indicated - the use of dental posts obtained from natural teeth. This article presents, through a clinical case, important details for the execution of the technique.


Subject(s)
Humans , Male , Middle Aged , Dental Bonding , Dental Pins , Post and Core Technique , Tooth Preparation, Prosthodontic , Biological Specimen Banks
8.
J. appl. oral sci ; 16(2): 111-115, Mar.-Apr. 2008. ilus, tab
Article in English | LILACS, BBO | ID: biblio-873411

ABSTRACT

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey’s test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.


Subject(s)
Acrylic Resins , Dental Prosthesis, Implant-Supported , Dental Restoration, Temporary , Dental Materials , Materials Testing
9.
RFO UPF ; 13(1): 48-54, jan.-abr. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-487410

ABSTRACT

Este estudo investigoua resistência à remoção por tração de pinos de fibra de vidro e o padrão de falhas ocorrido em função do grau de adaptação dos pinos ao conduto radicular. Foram selecionados quarenta caninos superiores humanos, com uma média de noventa dias de extração. Antes e durante o experimento, armazenaram-se os dentes em condições úmidas (soro fisiológico). Após tratamento endodôntico, seccionou-se a coroa desses dentes para que os remanescentes radiculares fossem padronizados com o comprimento médio de 15 mm, com um diâmetro de 5 a 5,5 mm no sentido mesiodistal e com diâmetro de 7 a 7,5 mm no sentido vestibulopalatino. As raízes foram aleatoriamente distribuídas em quatro grupos (n = 10): no Grupo 1, todo o conduto foi preparado com broca Largo 4®; no Grupo 2, o conduto foi preparado como no Grupo 1 e, após, o terço cervical foi alargado com ponta diamantada 1016 HL; no Grupo 3, após o preparo inicial como feito no Grupo 1, os terços cervical e médio foram alargados com ponta diamantada 1016 HL; no Grupo 4, todo o conduto foi alargado com ponta diamantada 1016 HL. Os condutos foram preparados com 9 mm de profundidade e pinos Reforpost nº 2® foram cimentados com adesivo Scoth Bond Multi-Uso Plus® e cimento resinoso RelyX CRA®. A porção coronária do núcleo foi construída com resina composta Filtek Z250®. Após 24h de armazenamento, os espécimes foram submetidos a testes de resistência à remoção por tração em máquina de ensaios universal Kratos modelo K-2000MP®, na velocidade de 0,5 mm/min. Os seguintes valores foram encontrados: Grupo 1 - 47,67 kgf (d.p. = 12,80); Grupo 2 - 40,92 kgf (d.p. = 9,94); Grupo 3 - 43,63 kgf (d.p. = 9,30); Grupo 4 - 37,57 kgf (d.p. = 8,62). Não houve diferença estatisticamente significativa entre os grupos (p < 0,05). Nos Grupos 1,2 e 3 o padrão de falha mais comum foi adesivo (interface dentina-cimento) e, no Grupo 4, houve 50 por cento de falhas adesivas e 40 por cento de falhas combinadas.


Subject(s)
Dental Cements , Dental Pins , Dental Pulp Cavity , Tensile Strength
10.
J. appl. oral sci ; 16(2): 111-115, Mar.-Apr. 2008. ilus, tab
Article in English | LILACS | ID: lil-479755

ABSTRACT

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.


Subject(s)
Humans , Dental Prosthesis, Implant-Supported , Denture Design , Denture, Partial, Temporary , Dental Materials/chemistry , Glass/chemistry , Nylons/chemistry , Acrylic Resins/chemistry , Crowns , Dental Abutments , Dental Restoration Failure , Materials Testing , Pliability , Pressure , Polymers/chemistry , Stress, Mechanical , Surface Properties
11.
Rev. dent. press ortodon. ortopedi. facial ; 13(2): 34-39, mar.-abr. 2008. ilus
Article in Portuguese | LILACS | ID: lil-480101

ABSTRACT

OBJETIVO: esta revisão de literatura visa avaliar, através de literatura específica, a sensibilidade e especificidade do exame de ressonância magnética (RM) para o diagnóstico dos desarranjos internos da articulação temporomandibular (ATM). METODOLOGIA: tanto artigos que utilizaram ATM de cadáveres para comparar achados anatômicos aos achados de ressonância magnética (RM), como artigos que compararam achados clínicos com achados de RM foram utilizados. Através dos achados desses artigos, as propriedades de sensibilidade e especificidade da RM para o diagnóstico de desarranjos internos da ATM foram calculadas. Com isso, a confiabilidade e a aplicabilidade do exame de RM no diagnóstico dos desarranjos internos da ATM foram discutidas. RESULTADOS: encontrou-se sensibilidade de 90 por cento e especificidade de 88 por cento da RM para desarranjos internos da ATM. CONCLUSÃO: o exame de RM de ATM possui ótima sensibilidade e especificidade para o diagnóstico dos desarranjos internos da ATM. Porém, tal exame deve ser solicitado com cautela, apenas nos casos onde a imagem seja indispensável para o plano de tratamento.


OBJECTIVE: the aim of this paper is to review the literature concerning the reliability and applicability of magnetic resonance imaging (MRI) in the diagnosis of temporomandibular joint (TMJ) internal disorders. METHODS: articles that have used TMJ from cadavers to compare MRI findings with anatomic findings, as well as some papers that have compared clinical findings with MRI findings were evaluated. According to the findings identified on these articles, the MRI sensitivity and specificity properties for the TMJ internal disorders diagnosis were calculated. Then, the MRI reliability and applicability for the TMJ internal disorders diagnosis were discussed. RESULTS: 90 percent of sensitivity and 88 percent of specificity were found. CONCLUSION: the TMJ MRI presents good sensitivity and specificity for the TMJ internal disorders diagnosis. But dentists should beware and request this exam only in cases where MRI will be essential to the treatment planning.


Subject(s)
Magnetic Resonance Spectroscopy , Temporomandibular Joint
12.
Rev. Assoc. Paul. Cir. Dent ; 61(6): 467-471, nov.-dez. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-540233

ABSTRACT

Os pinos de coloração escura, por não possuírem translucidez, foram sugeridos como materiais que podem afetar adversamente a estética das coroas ceramo-cerâmicas. O objetivo deste trabalho foi avaliar clinicamente se a translucidez das coroas ceramo-cerâmicas é influenciada pela opacidade e coloração do pino usado para a confecção da reconstrução coronária. O resultado estético do presente caso clínico mostrou-se independente das propriedades ópticas do pino intra-radicular usado. Contudo, outros fatores, como o tamanho e quantidade dos cristais, índice de refração e espessura da infra-estrutura cerâmica podem também influenciar a estética final das coroas ceramo-cerâmicas.


Because dark-colored posts do not present translucency, they have been suggested as materiais that may affect the esthetic outcome of all-ceramic crowns. The purpose of this work was to clinically evaluate if the translucency of all-ceramic crowns may be disturbed by the opacity and color of the post used for abutment tooth. The satisfactory esthetic outcome of the all-ceramic crowns has shown to be irrespective of the optical properties of the post at this case report. However, other factors, as the size and the quantity of crystals refraction index and ceramic thickness may also influence the final esthetics of all-ceramic crowns.


Subject(s)
Humans , Female , Middle Aged , Ceramics , Composite Resins , Dental Restoration, Permanent , Esthetics, Dental , Radiography
SELECTION OF CITATIONS
SEARCH DETAIL